beautypg.com

6 facility improved lock/unlock - @clck – Rainbow Electronics GM862-QUAD-PY User Manual

Page 89

background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 89 of 434

+CLCK - Facility Lock/Unlock

SELINT 2

- defines the operation to be done on the facility
0 - unlock facility
1 - lock facility
2 - query status
- shall be the same as password specified for the facility from

the DTE user interface or with command Change Password
+CPWD

- sum of integers each representing a class of information (default

is 7)

1 - voice (telephony)
2 - data (refers to all bearer services)
4 - fax (facsimile services)
8 - short message service
16 - data circuit sync
32 - data circuit async
64 - dedicated packet access
128 - dedicated PAD access

Note: when =2 and command successful, it returns:
+CLCK: [,[+CLCK: ,
[…]]

where
- the current status of the facility
0 - not active
1 - active
n> - class of information of the facility

AT+CLCK=?

Test command reports all the facilities supported by the device.

Reference GSM

07.07

Example

Querying such a facility returns an output on three

rows, the first for voice, the second for data, the
third for fax:

AT+CLCK =”AO”,2
+CLCK: ,1
+CLCK: ,2

+CLCK: ,4

3.5.4.3.6 Facility Improved Lock/Unlock - @CLCK

@CLCK - Facility Improved Lock/Unlock

SELINT 0 / 1

AT@CLCK=
,
[,
[,]]

Execution command is used to lock or unlock a ME o a network facility.

Parameters:
- facility
"SC" - SIM (PIN request) (device asks SIM password at power-up and

when this lock command issued)