6 fax class 1 at commands, 1 general configuration, 1 manufacturer id - +fmi – Rainbow Electronics GM862-QUAD-PY User Manual
Page 233: 2 model id - +fmm, 3 revision id - +fmr, 2 transmission/reception control, 1 stop transmission and pause - +fts

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 233 of 434
3.5.6 FAX Class 1 AT Commands
3.5.6.1 General Configuration
3.5.6.1.1 Manufacturer ID - +FMI
+FMI - Manufacturer ID
SELINT 0
AT+FMI?
Read command reports the manufacturer ID. The output depends on the
choice made through #SELINT command.
Example
AT+FMI?
Telit_Mobile_Terminals
OK
Reference
ITU T.31 and TIA/EIA-578-A specifications
+FMI - Manufacturer ID
SELINT 1 / 2
AT+FMI?
Read command reports the manufacturer ID. The output depends on the
choice made through #SELINT command.
Example
AT+FMI?
Telit
OK
Reference
ITU T.31 and TIA/EIA-578-A specifications
3.5.6.1.2 Model ID - +FMM
+FMM - Model ID
SELINT 0 / 1 / 2
AT+FMM?
Read command reports the model ID
Reference
ITU T.31 and TIA/EIA-578-A specifications
3.5.6.1.3 Revision ID - +FMR
+FMR - Revision ID
SELINT 0 / 1 / 2
AT+FMR?
Read command reports the software revision ID
Reference
ITU T.31 and TIA/EIA-578-A specifications
3.5.6.2 Transmission/Reception Control
3.5.6.2.1 Stop Transmission And Pause - +FTS
+FTS - Stop Transmission And Pause
SELINT 0 / 1 / 2
AT+FTS=
Execution command causes the modem to terminate a transmission and
wait for 10ms intervals before responding with OK result.
Parameter: