#GPPPCFG - PPP-GPRS Parameters Configuration
SELINT 2
1 - active mode, the module starts autonomously the LCP negotiation
immediately after the CONNECT message
Note: if
assigned to the host application is the previous remote IP Address
obtained by the Network.
AT# GPPPCFG?
Read command reports the current PPP-GPRS connection parameters in
the format:
#GPPPCFG:
AT# GPPPCFG=?
Test command returns the range of supported values for parameter
#PPPCFG: “”,(10-600),(0,1)
3.5.7.1.81 RTC Status - #RTCSTAT
#RTCSTAT - RTC Status
SELINT 0 / 1
AT#RTCSTAT[=
Set command resets the RTC status flag.
Parameter:
Note: the initial value of RTC status flag is RTC HW Error and it doesn’t
change until a command AT#RTCSTAT=0 is issued.
Note: if a power failure occurs and the buffer battery is down the RTC
status flag is set to 1. It doesn’t change until command AT#RTCSTAT=0 is
issued.
Note: if parameter
the same as Read command.
AT#RTCSTAT?
Read command reports the current value of RTC status flag, in the format:
#RTCSTAT:
AT#RTCSTAT=?
Test command returns the range of supported values for parameter
#RTCSTAT - RTC Status
SELINT 2