#CBC- Battery And Charger Status

SELINT 0 / 1

AT#CBC?

Read command has the same meaning as Execution command.

AT#CBC=?

Test command returns the OK result code.


#CBC- Battery And Charger Status

SELINT 2

AT#CBC

Execution command returns the current Battery and Charger state in the
format:

#CBC: ,

where:
- battery charger state
0 - charger not connected
1 - charger connected and charging
2 - charger connected and charge completed
- battery voltage in units of ten millivolts: it is the real

battery voltage only if charger is not connected; if the charger is
connected this value depends on the charger voltage.

AT#CBC=?

Test command returns the OK result code.

3.5.7.1.41 GPRS Auto-Attach Property - #AUTOATT

#AUTOATT - Auto-Attach Property

SELINT 0 / 1

AT#AUTOATT
[=]

Set command enables/disables the TE GPRS auto-attach property.

Parameter:

0 - disables GPRS auto-attach property
1 - enables GPRS auto-attach property (factory default): after the

command #AUTOATT=1 has been issued (and at every following
startup) the terminal will automatically try to attach to the GPRS service.


Note: If parameter is omitted then the behaviour of Set command is the
same as Read command.

AT#AUTOATT?

Read command reports whether the auto-attach property is currently
enabled or not, in the format:

#AUTOATT:

AT#AUTOATT=?

Test command reports available values for parameter .


#AUTOATT - Auto-Attach Property

SELINT 2

AT#AUTOATT=
[]

Set command enables/disables the TE GPRS auto-attach property.

Parameter:

0 - disables GPRS auto-attach property
1 - enables GPRS auto-attach property (factory default): after the