Rainbow Electronics GM862-QUAD-PY User Manual
Page 182

 
 
 
 
AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 182 of 434
+CSCB -Select Cell Broadcast Message Types
SELINT 0 / 1
[
[,
[,
 
received by the device. 
 
Parameter: 
 0 - the message types defined by 
(factory default)
 1 - the message types defined by 
combinations of the CBM message identifiers; default is empty 
string (“”). 
combinations of CBM data coding schemes; default is empty string 
(“”). 
 
Note: the current settings are stored through +CSAS 
 
Note: issuing AT+CSCB
 
Note: issuing AT+CSCB=
AT+CSCB=0
AT+CSCB?
Read command reports the current value of parameters 
and 
AT+CSCB=?
Test command returns the range of values for parameter 
Example
AT+CSCB?
+CSCB: 1,"","" 
 
OK 
(all CBMs are accepted, none is rejected)
AT+CSCB=0,"0,1,300-315,450","0-3" 
OK 
Reference
GSM 07.05, GSM 03.41, GSM 03.38.
 
CSCB -Select Cell Broadcast Message Types 
SELINT 2
AT+CSCB= 
[
[,
Set command selects which types of Cell Broadcast Messages are to be 
received by the device. 
 
Parameters: 
 0 - the message types defined by 
(factory default)
 1 - the message types defined by 
combinations of the CBM message identifiers; default is empty 
string (“”). 
combinations of CBM data coding schemes; default is empty string 
(“”). 