19 accumulated call meter maximum - +camm – Rainbow Electronics GM862-QUAD-PY User Manual
Page 144

 
 
 
 
AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 144 of 434
+CACM - Accumulated Call Meter
SELINT 2
 
Parameter: 
after startup, it is required no more
AT+CACM?
Read command reports the current value of the SIM ACM in the format: 
 
+CACM: 
where: 
the ACM value in hexadecimal format (e.g. “00001E” indicates 
decimal value 30) 
 
Note: the value 
defined with command +CPUC 
AT+CACM=?
Test command returns the OK result code
Reference GSM
07.07
3.5.4.4.19 Accumulated Call Meter Maximum - +CAMM
+CAMM - Accumulated Call Meter Maximum
SELINT 0 / 1
AT+CAMM[= 
[,
Set command sets the Advice of Charge related Accumulated Call Meter 
Maximum Value stored in SIM (ACMmax). This value represents the 
maximum number of home units allowed to be consumed by the subscriber. 
When ACM reaches 
 
Parameter: 
home units allowed to be consumed by the subscriber.
is required no more
 
Note: 
 
Note: if the parameters are omitted the behavior of Set command is the 
same as Read command. 
AT+CAMM?
Read command reports the ACMmax value stored in SIM in the format: 
 
+CAMM : 
where: 
ACMmax value in hexadecimal format (e.g. “00001E” indicates 
decimal value 30) 
Reference GSM
07.07