19 accumulated call meter maximum - +camm – Rainbow Electronics GM862-QUAD-PY User Manual
Page 144

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 144 of 434
+CACM - Accumulated Call Meter
SELINT 2
Parameter:
after startup, it is required no more
AT+CACM?
Read command reports the current value of the SIM ACM in the format:
+CACM:
where:
the ACM value in hexadecimal format (e.g. “00001E” indicates
decimal value 30)
Note: the value
defined with command +CPUC
AT+CACM=?
Test command returns the OK result code
Reference GSM
07.07
3.5.4.4.19 Accumulated Call Meter Maximum - +CAMM
+CAMM - Accumulated Call Meter Maximum
SELINT 0 / 1
AT+CAMM[=
[,
Set command sets the Advice of Charge related Accumulated Call Meter
Maximum Value stored in SIM (ACMmax). This value represents the
maximum number of home units allowed to be consumed by the subscriber.
When ACM reaches
Parameter:
home units allowed to be consumed by the subscriber.
is required no more
Note:
Note: if the parameters are omitted the behavior of Set command is the
same as Read command.
AT+CAMM?
Read command reports the ACMmax value stored in SIM in the format:
+CAMM :
where:
ACMmax value in hexadecimal format (e.g. “00001E” indicates
decimal value 30)
Reference GSM
07.07