Rainbow Electronics GM862-QUAD-PY User Manual
Page 282

 
 
 
 
AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 282 of 434
#DIALMODE - ATD Dialing Mode
SELINT 0 / 1
1 - (voice call only) OK result code is received only after the called party
answers. Any character typed aborts the call and NO CARRIER result 
code is received. 
2 - (voice call and data call) the following custom result codes are
received, monitoring step by step the call status:
DIALING (MO in progress) 
RINGING (remote ring) 
CONNECTED (remote call accepted) 
RELEASED (after ATH) 
DISCONNECTED (remote hang-up) 
 
Note: The setting is saved in NVM and available on following reboot. 
 
Note: In case a BUSY tone is received and at the same time ATX0 is 
enabled ATD will return NO CARRIER instead of DISCONNECTED. 
 
Note: if parameter 
same as Read command. 
AT#DIALMODE?
Read command returns current ATD dialing mode in the format: 
 
#DIALMODE: 
AT#DIALMODE=?
Test command returns the range of values for parameter 
 
#DIALMODE - Dialing Mode 
SELINT 2
AT#DIALMODE= 
[
Set command sets dialing modality. 
 
Parameter: 
ringing (factory default)
1 – (voice call only) OK result code is received only after the called party
answers. Any character typed aborts the call and OK result code is 
received. 
2 - (voice call and data call) the following custom result codes are
received, monitoring step by step the call status:
DIALING (MO in progress) 
RINGING (remote ring) 
CONNECTED (remote call accepted) 
RELEASED (after ATH) 
DISCONNECTED (remote hang-up) 
 
Note: In case a BUSY tone is received and at the same time ATX0 is 
enabled ATD will return NO CARRIER instead of DISCONNECTED. 
 
Note: The setting is saved in NVM and available on following reboot. 
AT#DIALMODE?
Read command returns current ATD dialing mode in the format: 
 