+CIND - Indicator Control
SELINT 2
0 - registered to home network or not registered
1 - registered to other network
“smsfull” - a short message memory storage in the MT has become full (1),
or memory locations are available (0)
0 - memory locations are available
1 - a short message memory storage in the MT has become full.
“rssi” - received signal (field) strength
0 - signal strength ≤ (-112) dBm
1..4 - signal strength in (-97) dBm..(-66) dBm (15 dBm steps)
5 - signal strength ≥ (-51) dBm
99 - not measurable
Example
Next command causes all the indicators to be registered
AT+CIND=1,1,1,1,1,1,1,1,1
Next command causes all the indicators to be de-
registered
AT+CIND=0,0,0,0,0,0,0,0,0
Next command to query the current value of all
indicators
AT+CIND?
CIND: 4,0,1,0,0,0,0,0,2
OK
Note See
command
+CMER
Reference GSM
07.07
3.5.4.4.6 Mobile Equipment Event Reporting - +CMER
+CMER - Mobile Equipment Event Reporting
SELINT 2
AT+CMER=
[
[,
[,
[,
[,
Set command enables/disables sending of unsolicited result codes from
TA to TE in the case of indicator state changes (n.b.: sending of URCs in
the case of key pressings or display changes are currently not
implemented).
Parameters:
0 - discard +CIEV Unsolicited Result Codes.
1 - discard +CIEV Unsolicited Result Codes when TA-TE link is reserved
(e.g. on-line data mode); otherwise forward them directly to the TE.
2 - buffer +CIEV Unsolicited Result Codes in the TA when TA-TE link is
reserved (e.g. on-line data mode) and flush them to the TE after
reservation; otherwise forward them directly to the TE.
3 - forward +CIEV Unsolicited Result Codes directly to the TE; when TA is
in on-line data mode each +CIEV URC is replaced with a Break (100
ms), and is stored in a buffer; onche the ME goes into command mode