beautypg.com

23 query temperature overflow - #qtemp – Rainbow Electronics GM862-QUAD-PY User Manual

Page 253

background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 253 of 434

#WAKE - Wake From Alarm Mode

SELINT 2

AT#WAKE?

Read command returns the operating status of the device in the format:

#WAKE:

where:

0 - normal operating mode
1 - alarm mode or normal operating mode with some alarm activity.

3.5.7.1.23 Query Temperature Overflow - #QTEMP

#QTEMP - Query Temperature Overflow

SELINT 0 / 1

AT#QTEMP
[=]

Set command has currently no effect. The interpretation of parameter
is currently not implemented.
Note: if parameter is omitted the behaviour of Set command is the
same as Read command

Note: Only =0 is accepted.

AT#QTEMP?

Read command queries the device internal temperature sensor for over
temperature and reports the result in the format:

#QTEMP:
where
- over temperature indicator
0 - the device temperature is in the working range
1 - the device temperature is out of the working range

Note: typical temperature working range is (-10°C..+55°C); anyway you are
strongly recommended to consult the “Hardware User Guide” to verify the
real temperature working range of your module

#QTEMP=?

Test command reports supported range of values for parameter .

Note

The device should not be operated out of its temperature working range; if
temperature is out of range proper functioning of the device is not ensured.


#QTEMP - Query Temperature Overflow

SELINT 2

AT#QTEMP=
[]

Set command has currently no effect. The interpretation of parameter
is currently not implemented: any value assigned to it will simply
have no effect.

AT#QTEMP?

Read command queries the device internal temperature sensor for over
temperature and reports the result in the format:

#QTEMP:

where