1 select interface style - #selint – Rainbow Electronics GM862-QUAD-PY User Manual
Page 33

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 33 of 434
3.5.2.1.1 Select Interface Style - #SELINT
#SELINT - Select Interface Style
SELINT 0 / 1
AT#SELINT[=
Set command sets the AT command interface style depending on
parameter
Parameter:
0 - switches the AT command interface of the products, to the GM862-
GSM and GM862-GPRS interface style
1 - switches the AT command interface of the products, to the GM862-
PCS, PYTHON, QUAD-PY, TRIZIUM and GE863-QUAD, PY interface
style
2 - switches the AT command interface style of the product, to the new
products like GE864, GC864 and the GPS products
15
Note: If parameter is omitted then the behaviour of Set command is the
same as read command.
AT#SELINT?
Read command reports the current interface style.
AT#SELINT=?
Test command reports the available range of values for parameter
Note
It’s suggested to reboot the module after every #SELINT setting.
#SELINT - Select Interface Style
SELINT 2
AT#SELINT=[
Set command sets the AT command interface style depending on
parameter
Parameter:
0 - switches the AT command interface of the products, to the GM862-
GSM and GM862-GPRS interface style
1 - switches the AT command interface of the products, to the GM862-
PCS, PYTHON, QUAD-PY, TRIZIUM and GE863-QUAD, PY interface
style
2 - switches the AT command interface style of the product, to the new
products like GE864, GC864 and the GPS products
12
AT#SELINT?
Read command reports the current interface style.
AT#SELINT=?
Test command reports the available range of values for parameter
Note
It’s suggested to reboot the module after every #SELINT setting.
Note Issuing
AT#SELINT=
channel has been enabled (see +CMUX) causes an ERROR result code to
be returned.
Note Issuing
AT#SELINT=
enabled (see #ENS) causes an ERROR result code to be returned.
15
Under the #SELINT=2, all the new functionalities like CMUX, SAP, Multisocket are available. Moreover, all the
AT commands have been improved according to the ETSI specifications.