AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 34 of 434
3.5.3 Hayes Compliant AT Commands
3.5.3.1 Generic Modem Control
3.5.3.1.1 Set To Factory-Defined Configuration - &F
&F - Set To Factory-Defined Configuration
SELINT 0 / 1 / 2
AT&F[
Execution command sets the configuration parameters to default values 
specified by manufacturer; it takes in consideration hardware configuration 
switches and other manufacturer-defined criteria. 
 
Parameter: 
 0 - just the factory profile base section parameters are considered. 
 1 - either the factory profile base section and the extended section are 
considered (full factory profile). 
 
Note: if parameter 
behaviour as AT&F0 
Reference V25ter. 
 
3.5.3.1.2 Soft Reset - Z
Z - Soft Reset
SELINT 0 / 1 / 2
ATZ[
Execution command loads the base section of the specified user profile and 
the extended section of the default factory profile. 
 
Parameter: 
 0..1 - user profile number 
 
Note: any call in progress will be terminated. 
 
Note: if parameter 
ATZ0. 
Reference V25ter. 
 
3.5.3.1.3 Select Active Service Class - +FCLASS
+FCLASS - Select Active Service Class
SELINT 0 / 1 / 2
AT+FCLASS=
Set command sets the wireless module in specified connection mode (data, 
fax, voice), hence all the calls done afterwards will be data or voice. 
 
Parameter: 