6 receive data with hdlc framing - +frh, 3 serial port control, 1 select flow control specified by type - +flo – Rainbow Electronics GM862-QUAD-PY User Manual
Page 236

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 236 of 434
+FTH - Transmit Data With HDLC Framing
SELINT 0 / 1 / 2
HDLC protocol and the modulation defined by the parameter
Parameter:
3 - V21/300 bps
AT+FTH=?
Test command returns all supported values of the parameter
Note: test command result is without command echo.
Reference
ITU T.31 and TIA/EIA-578-A specifications
3.5.6.2.6 Receive Data With HDLC Framing - +FRH
+FRH - Receive Data With HDLC Framing
SELINT 0 / 1 / 2
AT+FRH=
Execution command causes the module to receive facsimile data using
HDLC protocol and the modulation defined by the parameter
Parameter:
3 - V21/300 bps
AT+FRH=?
Test command returns all supported values of the parameter
Note: test command result is without command echo.
Reference
ITU T.31 and TIA/EIA-578-A specifications
3.5.6.3 Serial Port Control
3.5.6.3.1 Select Flow Control Specified By Type - +FLO
+FLO - Select Flow Control Specified By Type
SELINT 0 / 1 / 2
AT+FLO=
Set command selects the flow control behaviour of the serial port in both
directions: from DTE to DTA and from DTA to DTE.
Parameter:
0 - flow control None
1 - flow control Software (XON-XOFF)
2 - flow control Hardware (CTS-RTS) – (factory default)
Note: This command is a shortcut of the +IFC command.
Note: +FLO’s settings are functionally a subset of &K’s ones.
AT+FLO?
Read command returns the current value of parameter
with the parameter that is not allowed by AT+FLO the read
command AT+FLO? will return: