78 escape sequence guard time - #e2esc – Rainbow Electronics GM862-QUAD-PY User Manual
Page 305

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 305 of 434
#SKIPESC - Skip Escape Sequence
SELINT 0 / 1
Parameter:
default).
1 - skips the escape sequence; its transmission is not enabled.
Note: in case of an FTP connection, the escape sequence is not
transmitted, regardless of the command setting.
Note: issuing AT#SKIPESC
command.
Note: issuing AT#SKIPESC=
AT#SKIPESC=0
AT#SKIPESC?
Read command reports whether escape sequence skipping is currently
enabled or not, in the format:
#SKIPESC:
AT#SKIPESC=?
Test command reports supported range of values for parameter
#SKIPESC - Skip Escape Sequence
SELINT 2
AT#SKIPESC=
[
Set command enables/disables skipping the escape sequence +++ while
transmitting during a data connection.
Parameter:
default).
1 - skips the escape sequence; its transmission is not enabled.
Note: in case of an FTP connection, the escape sequence is not
transmitted, regardless of the command setting.
AT#SKIPESC?
Read command reports whether escape sequence skipping is currently
enabled or not, in the format:
#SKIPESC:
AT#SKIPESC=?
Test command reports supported range of values for parameter
3.5.7.1.78 Escape Sequence Guard Time - #E2ESC
#E2ESC - Escape Sequence Guard Time