77 skip escape sequence - #skipesc – Rainbow Electronics GM862-QUAD-PY User Manual
Page 304

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 304 of 434
#AUTOBND - Automatic Band Selection
SELINT 0 / 1
90 seconds through available bands until a GSM cell is found.
Note: if parameter
same as Read command.
AT#AUTOBND?
Read command returns whether the automatic band selection is enabled or
not in the format:
#AUTOBND:
AT#AUTOBND=?
Test command returns the range of supported values for parameter
#AUTOBND - Automatic Band Selection
SELINT 2
AT#AUTOBND=
[
Set command enables/disables the automatic band selection at power-on.
Parameter:
0 - disables automatic band selection at next power-up (factory default)
1 - enables automatic band selection at next power-up; the automatic
band selection stops as soon as a GSM cell is found.
2 - enables automatic band selection in four bands (at 850/1900 and
900/1800); differently from previous settings it takes immediate effect
Note: necessary condition to effectively have automatic band selection at
next power-up (due to either AT#AUTOBND=1 or AT#AUTOBND=2) is that
AT+COPS=0 has to be previously issued
Note: if automatic band selection is enabled the band changes every about
90 seconds through available bands until a GSM cell is found.
Note: if the current setting is different from AT#AUTOBND=2 and we’re
issuing AT#ENS=1, at first next power-up after the ENS functionality has
been activated (see #ENS) the automatic band selection
(AT#AUTOBND=1) is enabled.
AT#AUTOBND?
Read command returns whether the automatic band selection is enabled or
not in the form:
#AUTOBND:
AT#AUTOBND=?
Test command returns the range of supported values for parameter
3.5.7.1.77 Skip Escape Sequence - #SKIPESC
#SKIPESC - Skip Escape Sequence
SELINT 0 / 1
AT#SKIPESC[=
[
Set command enables/disables skipping the escape sequence +++ while
transmitting during a data connection.