#DSCRIPT - Delete Script
SELINT 0 / 1
sensitive)
Note: if the file
Example
AT#DSCRIPT="Third.py"
OK
#DSCRIPT - Delete Script
SELINT 2
AT#DSCRIPT=
[
Execution command deletes a file from Easy Script® related NVM memory.
Parameter:
sensitive)
Note: if the file
Example
AT#DSCRIPT="Third.py"
OK
3.5.7.10.8 Reboot - #REBOOT
#REBOOT - Reboot
SELINT 0 / 1
AT#REBOOT
Execution command reboots immediately the unit.
It can be used to reboot the system after a remote update of the script in
order to have the new one running.
AT#REBOOT?
Read command has the same behavior of Execution command.
Example
AT#REBOOT
…. Module Reboots …
Note
This command does not return result codes.
#REBOOT - Reboot
SELINT 2
AT#REBOOT
Execution command reboots immediately the unit.
It can be used to reboot the system after a remote update of the script in
order to have the new one running.
Example
AT#REBOOT
…. Module Reboots …
Note
This command does not return result codes.
3.5.7.10.9
CMUX Interface Enable - #CMUXSCR
#CMUXSCR - CMUX Interface Enable
SELINT 2
AT#CMUXSCR=
Set command enables/disables the GSM 07.10 multiplexing protocol control