beautypg.com

4 ftp at commands, 1 ftp time-out - #ftpto, 2 ftp open - #ftpopen – Rainbow Electronics GM862-QUAD-PY User Manual

Page 326

background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 326 of 434

3.5.7.4 FTP AT Commands

3.5.7.4.1 FTP Time-Out - #FTPTO

#FTPTO - FTP Time-Out

SELINT 0 / 1

AT#FTPTO[=
]

Set command sets the time-out used when opening either the FTP control
channel or the FTP traffic channel.

Parameter:
- time-out in 100 ms units
100..5000 - hundreds of ms (factory default is 100)

Note: The parameter is not saved in NVM.

Note: if parameter is omitted the behaviour of Set command is the
same as Read command.

AT#FTPTO?

Read command returns the current FTP operations time-out, in the format:

#FTPTO:

AT#FTPTO=?

Test command returns the range of supported values for parameter



#FTPTO - FTP Time-Out

SELINT 2

AT#FTPTO=
[]

Set command sets the time-out used when opening either the FTP control
channel or the FTP traffic channel.

Parameter:
- time-out in 100 ms units
100..5000 - hundreds of ms (factory default is 100)

Note: The parameter is not saved in NVM.

AT#FTPTO?

Read command returns the current FTP operations time-out, in the format:

#FTPTO:

AT#FTPTO=?

Test command returns the range of supported values for parameter

3.5.7.4.2 FTP Open - #FTPOPEN

#FTPOPEN - FTP Open

SELINT 0 / 1

AT#FTPOPEN=
,
,
,

Execution command opens an FTP connection toward the FTP server.

Parameters:
- string type, address and port of FTP server (factory default

port 21).

- string type, authentication user identification string for FTP.
- string type, authentication password for FTP.

0 - active mode (default)