Parameters, Fixed parameters, Table 7: fixed parameters – Yaskawa MP940 Reference Manual User Manual
Page 504

MotionSuite™ MP940 Machine Controller Reference Manual
Parameters
A-17
Parameters
The following table details the meaning of each parameter, and the difference between
use/non-use.
Fixed Parameters
These parameters are normally not changed after being set, insofar as the
machine configuration/specifications do not change. Set these in the
MotionWorks™ Fixed Parameter Setting screen.
Table 7: Fixed Parameters
No.
Name
Setting Range
(Bit Name)
Meaning
Note
1
Axis Enabled
0 or 1
(default = 6)
0: Non-use selection
1: Use selection
—
13
Latch Input Signal
Type
0 or 1
(default = 0)
0: DI input signal
1: C-pulse input signal
—
14
Functions
Bit 0~1: Unused
—
—
Bit 2: LIMITSEL
Limit Switch Signal
Selection
0: OBC001F use
1: DI Signal Use
Bit 3~6: Unused
—
—
Bit 7: MCMDSEL
Motion Command Use
Selection
0: Unused / 1: Used
Bit 8~15: Unused
—
—
15
Unused
—
—
—
16
Simulation Mode
0~2
(default =0)
0: Normal Run Mode
—
1: Simulation Mode
17
Servo Axis
Functionality
Bit 0~3: 0~7
CMD_UNIT
Command Unit Selection
0: pulse (electronic
gearing disabled)
1: mm
2: deg
3: inch
Bit 4: USE_GEAR
Electronic Gearing Selection
0: Enable / 1: Disable
Bit 5: PMOD_SEL
Axis Selection
0: Limited-length
Axis
1: Infinite-length Axis
Bit 6: USE_BKRSH
Enable Backlash Compensa-
tion Selection
0: Enable / 1: Disable
Bit 7: USE_SLIMP
Enable Soft Limit (forward
Selection
0: Enable / 1: Disable