Gain related parameters (continued) – Yaskawa MP940 Reference Manual User Manual
Page 269

MotionSuite™ MP940 Machine Controller Reference Manual
SGDH User Parameters
6-69
Pn10E
Mode Switch
(acceleration)
10rpm/s
0 ~ 3000
When Pn10B.0 = 2 assuming acceleration
as the detection point, the speed loop is in
P control when the motor acceleration is at
or above the speed set in user parameter
Pn10E.
Usage Example
During accel/decel, torque saturation may
occur, resulting in motor speed
undershoot or overshoot when constant PI
control without the use of mode switches
is assumed.Supress torque saturation ans
eliminate motor speed overshoot and
undershoot by using the mode switches.
0
Speed
Torque
Position
Pn10F
Mode Switch
(error pulse)
Command
Unit
0 ~ 10000
Cannot be used when used in connection
with an MP940.
0
Position
Gain Related Parameters (Continued)
User
Parameter
Number
Digital
Position
Name
(setting
range)
Content
Default
Setting
Control
Mode
Motor Acceleration
PI Control
P Control
PI Control
P Control
+Pn10E
0 acceleration
-Pn10E
PI Control
Motor Speed
Reference Speed
Speed
Overshoot
Under-
shoot
Motor
Speed
Time
w/o Mode Switch
w/ Mode Switch
Motor
Speed
Time
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)