System error status – Yaskawa MP940 Reference Manual User Manual
Page 339

MotionSuite™ MP940 Machine Controller Reference Manual
System Errors
9-11
The list containing the system error status appears below.
System Error Status
Name
Register Number
Content
Error Type
SW00050
0001H
Watchdog Timeout
0002H
Bus Timeout
0006H
Break-point Interrupt Execution
0007H
BOUND Error (boundary check error)
0008H
Undefined Command Execution
000CH
Duplication Fault
000DH
Invalid TSS
000EH
Segment Invalidity
000FH
Stack Error
0010H
General Protection Error
0011H
Page Fault
0012H
Data Alignment Error
0014H
Time Allocation Error
0041H
ROM Diagnostic Error
0042H
RAM Diagnostic Error
0043H
CPU Diagnostic Error
0044H
FPU Diagnostic Error
Error Code
SW00051
For system error analysis
Error IP
SW00052
For system error analysis
Error CS
SW00053
For system error analysis
Error Task
SW00054
0000H: System
0003H: DWG.H
0001H: DWG.A
0004H: DWG.S
0002H: DWG.I
0005H: DWG.L
By Program Type
SW00055
0000H: System
0004H: DWG.S
0001H: DWG.A
0005H: DWG.L
0002H: DWG.I
0008H: Functions
0003H: DWG.H
0010H: Main motion
program
0011H: Motion sub-program
Error Drawing Number SW00056
Source Drawing: FFFFH Function: 8xxxH
Sub-drawing: xx00H (Hxx: Sub-drawing Number)
Motion Program Number: FxxxH