Alarm Display List
The ON/OFF relationship between the “Alarm Display” and the “Alarm
Code Output” is shown in the table below:
Alarm Display and Alarm Code Output Relationship
Alarm
Display
Alarm Code Output
ALO1
ALO2
ALO3
Servo
Alarm
(ALM)
Output
Alarm Name
Alarm Content
A.02
x
Parameter
Breakdown*2
Servo amplifier
EEPROM data error
A.03
—
—
—
—
Main Circuit Detector
Error
Some power circuit
detection data is corrupt.
A.04
—
—
—
—
Parameter Setting
Error*2
A user parameter value
has been set outside the
setting range.
A.05
—
—
—
—
Mismatch Error
The capacities of the
motor and amplifier do
not match.
A.10
Overcurrent or Heat
Sink Overheat*2
Excessive current has
flowed to the IGBT, or
the servo amplifier heat
sink has overheated.
A.30
Regen Error
Regen Resistor
Disconnection
Regen Transistor Fault
A.32
—
—
—
—
Regen Overload
The regen energy
exceeds the capacity of
the regen resistor.
A.40
x
Overvoltage
The main circuit DC volt-
age is extremely high.
A.41
—
—
—
—
Undervoltage
The main circuit DC volt-
age is too low.
A.51
Overspeed
Servo motor speed is
extremely high.
A.71
Overload (Momentary
Maximum Load)
Motor has run for several
seconds or tens of sec-
onds at a torque greatly
exceeding the rated
value.
A.72
—
—
—
—
Overload (Continuous
Maximum Load)
The servo motor has
operated continuously at
a torque exceeding the
rated value.