MotionSuite™ MP940 Machine Controller Reference Manual
Parameter Details
6-37
41
STEP Distance OLC028
0 ~ 2
31-1
Sets the amount of motion in motion command
(OWC020) stepping feed in command units.
Unit: Command Unit
0
43
Home Offset
OLC02A
-2
31
~ 2
31-1
When the motion command (OWC020) is
Zero-point Return (ZRET), the axis moves
for a set distance after detection of an
enabled zero-return pulse, and then
stops. This position is the machine coor-
dinate zero point.
Unit: Command Unit
0
45
Speed Override OWC02C 0 ~ 32767
Override sets the output ratio with regard
to the feed speed (OWC022) setting in
outs of 0.01%.
10000
Enabled when the override selection of fixed parameter No. 17 (Bit 9 of motion controller
function selection flag) is enabled.
Other Command/Mode Settings (Continued)