Phase control – Yaskawa MP940 Reference Manual User Manual
Page 412

MotionSuite™ MP940 Machine Controller Reference Manual
Control Mode
11-15
Phase Control
Phase control is used to rotate an axis according to the transmitted speed
command, while at the same time excersizing strict control to a given number
of rotations. Electronic camming and electronic shafting can be achieved
using this control mode.
Complex device configurations can be alternated by the servo motors, and
phase matching, synchronous run, proportional run, and variable-speed cam
run can all be switched by the software. The figure below depicts a
schematic diagram of electronic camming/electronic shafting.
The order of operations in the phase control mode is shown below.
M
Drive
Controller
Gear
Gear
Gear
Cam
Roll No.1
Roll No.2
Cam
Machine
Machine Using Conventional
Synchronous Operation
(Line shaft, cam type)
Roll No.1
Roll No.2
Cam
Machine
M
M
M
MP920
Drive
Synchronous operation using the MP920
(Electronic shafting, electronic camming)
PCON
RUN
Position
Speed (%)
Time (t)
0
Standard
Speed
100%
Signifies system execution.
Signifies user setting
1. Setting of motion setting parameters
2. Phase control mode (PHCON) selection
3. Start of position control mode
Start of phase control operation
4. End of position control mode