beautypg.com

Vlt0101, Vlt0102 – Dell PowerEdge VRTX User Manual

Page 922

background image

VLT0101

Message

Processor module

arg1

voltage is less than the lower critical threshold.

Arguments

arg1 =

name

Detailed
Description

System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.

Recommended
Response Action

1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect
processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

VLT = Voltage

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Processor module voltage is outside of range. Contact support

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

VLT0102

Message

Processor module

arg1

voltage is greater than the upper warning threshold.

Arguments

arg1 =

name

Detailed
Description

System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.

Recommended
Response Action

1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect
processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

VLT = Voltage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

922