Psu0035, Psu0036 – Dell PowerEdge VRTX User Manual
Page 530

Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
An under voltage fault detected on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0035
Message
An over voltage fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
Check input power, replace or re-install the power supply. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Over voltage fault on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0036
Message
An over current fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
This failure may be the result of an electrical issue with cables or subsystem components in
the system.
530