Iov108, Iov010 – Dell PowerEdge VRTX User Manual
Page 300

IOV108
Message
Power fault detected on PCIE device
arg1
in
arg2arg3
.
Arguments
•
arg1 =
device name
•
arg2 =
slot type
•
arg3 =
slot number
Detailed
Description
The Chassis manager detected a power fault in an adapter after the adapter was powered on.
A power fauilt may be caused a damaged adapter or an adapter whose power requirements
exceed the maximum power limits of the slot.
Recommended
Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
a list of supported devices, contact the service provider.
Category
System Health
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
2554
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
IOV010
Message
A license is required to assign more than 2 PCIE slots to a server.
Detailed
Description
Non-licensed systems are only allowed two slots per server.
Recommended
Response Action
Import license which allows assignments of more than 2 PCIE slot per server.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
300