beautypg.com

Bat0014, Bat0015 – Dell PowerEdge VRTX User Manual

Page 92

background image

Category

System Health

SubCategory

BAT = Battery Event

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

BAT0014

Message

The storage battery for disk drive bay

arg1

is absent.

Arguments

arg1 =

bay

Detailed
Description

The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.

Recommended
Response Action

1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed,
reseat or reconnect the battery and cables. 3) Check the system logs for thermal related
issues.

Category

System Health

SubCategory

BAT = Battery Event

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Battery for disk drive bay is absent. Check battery.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

BAT0015

Message

The

arg1

battery is low.

Arguments

arg1 =

name

Detailed
Description

System settings may be preserved if input power is not removed from the power supplies.

92