Pdr37, Pdr38 – Dell PowerEdge VRTX User Manual
Page 446

Detailed
Description
The only physical disk available to be assigned as a hot spare is using SAS technology. The
physical disks in the virtual disk are using SATA technology. Because of this difference in
technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk
fails.
Recommended
Response Action
Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a
hot spare.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR37
Message
The
arg1
is not supported.
Arguments
•
arg1 =
physical device
Detailed
Description
The physical device may not have a supported version of the firmware or the physical device
may not be supported.
Recommended
Response Action
If the physical device is supported, then update the firmware to a supported version. If the
physical device is not supported, then replace the physical device with one that is supported.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR38
Message
A clear operation started on
arg1
.
446