beautypg.com

Pdr37, Pdr38 – Dell PowerEdge VRTX User Manual

Page 446

background image

Detailed
Description

The only physical disk available to be assigned as a hot spare is using SAS technology. The
physical disks in the virtual disk are using SATA technology. Because of this difference in
technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk
fails.

Recommended
Response Action

Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a
hot spare.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR37

Message

The

arg1

is not supported.

Arguments

arg1 =

physical device

Detailed
Description

The physical device may not have a supported version of the firmware or the physical device
may not be supported.

Recommended
Response Action

If the physical device is supported, then update the firmware to a supported version. If the
physical device is not supported, then replace the physical device with one that is supported.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR38

Message

A clear operation started on

arg1

.

446