Sel9900, Sel1506 – Dell PowerEdge VRTX User Manual
Page 704
![background image](/manuals/620821/704/background.png)
Category
System Health
SubCategory
SEL = Sys Event Log
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
SEL9900
Message
An unsupported event occurred.
Detailed
Description
The current software version cannot decode this event. The source of the event may come
from a source that is not compatible with this software or the event may have been added after
the release of this software. You may need to review this event using a tool which displays raw
data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended
Response Action
Upgrade Management Software
Category
System Health
SubCategory
SEL = Sys Event Log
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
SEL1506
Message
Lost communications with Chassis Group Member
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
The primary CMC has lost communication with the indicated member CMC.
Recommended
Response Action
Check network cable and network connections.
704