beautypg.com

Cpu0001, Cpu0002 – Dell PowerEdge VRTX User Manual

Page 140

background image

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

CPU0001

Message

CPU

arg1

has a thermal trip (over-temperature) event.

Arguments

arg1 =

number

Detailed
Description

The processor temperature increased beyond the operational range. Thermal protection shut
down the processor. Factors external to the processor may have induced this exception.

Recommended
Response Action

Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet
temperature (if available) and reinstall processor heatsink.

Category

System Health

SubCategory

CPU = Processor

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

CPU has a thermal trip. Check CPU heat sink

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

CPU0002

Message

CPU

arg1

has failed the built-in self-test (BIST).

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

140