Psu0041, Psu0042 – Dell PowerEdge VRTX User Manual
Page 543
![background image](/manuals/620821/543/background.png)
Trap/EventID
2185
LCD Message
Output under voltage fault detected on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0041
Message
An output over voltage fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
none
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Output over voltage fault on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0042
Message
An output over current fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
none
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
543