Enc13, Enc14 – Dell PowerEdge VRTX User Manual
Page 218

Trap/EventID
4339
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC13
Message
Unsupported configuration detected on
arg1
.
arg2arg3
Arguments
•
arg1 =
Enclosure Name
•
arg2 =
EMM0 1
•
arg3 =
EMM1 2
Detailed
Description
An unsupported configuration was detected. The SCSI rate of the Enclosure Management
Modules (EMMs) are not the same.
Recommended
Response Action
Replace one of the EMMs with the matching SCSI rate EMM.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 2 (Warning)
Trap/EventID
4338
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC14
Message
The number of enclosures connected on
arg1
has exceeded the maximum limit supported by the
controller.
Arguments
•
arg1 =
controller name
Detailed
Description
There are too many enclosures attached to the controller port. When the enclosure limit is
exceeded, the controller loses contact with all enclosures attached to the port. This is an
unsupported configuration.
218