Ctl46, Ctl47 – Dell PowerEdge VRTX User Manual
Page 184
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL46
Message
Single-bit ECC error. The
arg1
DIMM is critically degraded.
Arguments
•
arg1 =
Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may
occur..
Recommended
Response Action
Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the
controller battery pack. Refer to the storage hardware documentation for information on
replacing the DIMM.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 1 (Critical)
Trap/EventID
4329
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL47
Message
Single-bit ECC error on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may
occur. The DIMM must be replaced immediately.
Recommended
Response Action
Replace the DIMM immediately. The DIMM is a part of the controller battery pack. Refer to
your hardware documentation for information on replacing the DIMM.
Category
Storage
SubCategory
CTL = Storage Contr
184