Detailed
Description

An error involving multiple bits has been encountered during a read or write operation. The
error correction algorithm recalculates parity data during read and write operations. If an error
involves only a single bit, it may be possible for the error correction algorithm to correct the
error and maintain parity data. An error involving multiple bits, however, generally indicates
data loss. In some cases, if the multi-bit error occurs during a read operation, then the data on
the disk may be ok. If the multi-bit error occurs during a write operation, then data loss has
occurred.

Recommended
Response Action

Replace the Dual In-line Memory Module (DIMM). The DIMM is a part of the controller battery
pack. Refer to the storage hardware documentation for information on replacing the DIMM.
You may need to restore data from backup.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 1 (Critical)

Trap/EventID

4329

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL41

Message

Single-bit ECC error on

arg1

.

Arguments

arg1 =

Controller name

Detailed
Description

An error involving a single bit has been encountered during a read or write operation. The error
correction algorithm has corrected this error.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE