PWR8567

Message

Unable to turn off Server

arg1

on a power cycle action.

Arguments

arg1 =

server number

Detailed
Description

Unable to turn off the Server on a power cycle operation. This happens if the Server did not
show a "power off" status change within the expected time.

Recommended
Response Action

The Server could have taken more time to turn off than expected. If the Server is turned off,
turn on to complete the power cycle. If the Server has not completed a power cycle, retry the
operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8568

Message

Server

arg1

did not gracefully shutdown before the timer expired.

Arguments

arg1 =

slot number

Detailed
Description

The server identified in the message did not gracefully shutdown before the CMC shutdown
timer expired. This happens if the server did not show power off status change within 60
seconds after the operation was initiated, or if the OS in the server has not successfully
shutdown.

Recommended
Response Action

Check if the OS in the server identified in the message has successfully shutdown, if not,
manually complete the shutdown or wait for the shutdown to complete normally. If the issue
persists, perform a forced power down of the server identified in the message.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.