Trap/EventID
4331
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL74
Message
Preserved cache detected on
arg1
.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller has preserved data in the cache from a virtual disk, which it can no longer
locate. No data loss has occurred as the controller is saving these operations in its cache.
Recommended
Response Action
Check for the existence of a foreign configuration and import if any. Check that enclosures are
cabled correctly.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 2 (Warning)
Trap/EventID
4330
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL75
Message
Preserved cache discarded on
arg1
.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller cache was discarded by the user. Data may have been lost or corrupted.
Recommended
Response Action
If data was corrupted or lost, restore the data to the disk from a backup copy.
Category
Storage
SubCategory
CTL = Storage Contr
199