Pwr8575, Pwr8576 – Dell PowerEdge VRTX User Manual
Page 584
Recommended
Response Action
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting before retying the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 1 (Critical)
Trap/EventID
8417
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PWR8575
Message
Initated the Virtual Reseat of server
arg1
.
Arguments
•
arg1 =
server id
Detailed
Description
A Virtual Reseat for the server identified in the message is initiated. A Virtual Reseat is the
same as removing and inserting a server.
Recommended
Response Action
No response action is required.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
PWR8576
Message
Unable to turn on the Sleeve
arg1
after Virtual Reseat.
Arguments
•
arg1 =
sleeve number
584