beautypg.com

Pdr22, Pdr23 – Dell PowerEdge VRTX User Manual

Page 438

background image

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR22

Message

SMART warning temperature for

arg1

Arguments

arg1 =

PD Name

Detailed
Description

A disk has reached an unacceptable temperature and received a SMART alert (predictive
failure). The disk is likely to fail in the near future.

Recommended
Response Action

Do the following: 1) Determine why the physical disk reached an unacceptable temperature.
For example, a fan failure, incorrect thermostat settings, or the room temperature may be too
hot or cold. 2) Verify that the fans in the server or enclosure are working. 3) If the physical disk
is in an enclosure, check the thermostat settings and examine whether the enclosure is
located near a heat source. Verify the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
information. 4) If you cannot identify why the disk has reached an unacceptable temperature,
then replace the disk. If the physical disk is a member of a non-redundant virtual disk, then
back up the data before replacing the disk. Removing a physical disk that is included in a non-
redundant virtual disk causes the virtual disk to fail and may cause data loss.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR23

Message

SMART warning degraded for

arg1

Arguments

arg1 =

PD Name

438