Pdr22, Pdr23 – Dell PowerEdge VRTX User Manual
Page 438
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR22
Message
SMART warning temperature for
arg1
Arguments
•
arg1 =
PD Name
Detailed
Description
A disk has reached an unacceptable temperature and received a SMART alert (predictive
failure). The disk is likely to fail in the near future.
Recommended
Response Action
Do the following: 1) Determine why the physical disk reached an unacceptable temperature.
For example, a fan failure, incorrect thermostat settings, or the room temperature may be too
hot or cold. 2) Verify that the fans in the server or enclosure are working. 3) If the physical disk
is in an enclosure, check the thermostat settings and examine whether the enclosure is
located near a heat source. Verify the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
information. 4) If you cannot identify why the disk has reached an unacceptable temperature,
then replace the disk. If the physical disk is a member of a non-redundant virtual disk, then
back up the data before replacing the disk. Removing a physical disk that is included in a non-
redundant virtual disk causes the virtual disk to fail and may cause data loss.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR23
Message
SMART warning degraded for
arg1
Arguments
•
arg1 =
PD Name
438