Enc27, Enc28 – Dell PowerEdge VRTX User Manual
Page 225
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC27
Message
SAS or SATA mixing of physical disks is not supported within the
arg1
.
Arguments
•
arg1 =
Enclosure Name
Detailed
Description
The enclosure cannot support both SAS and SATA physical disks. Physical disks may be
disabled. This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 3 (Informational)
Trap/EventID
4339
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC28
Message
Enclosure Management Module (EMM) firmware version mismatch detected in
arg1
.
arg2arg3
.
Arguments
•
arg1 =
enclosure name
•
arg2 =
EMM 0 version
•
arg3 =
EMM 1 version
Detailed
Description
The firmware on the EMM modules is not the same version. Both modules must have the same
firmware version. This message is caused when you attempt to insert an EMM module that has
a different firmware version than an existing module.
Recommended
Response Action
Upgrade to the same version of the firmware on both EMM modules.
Category
Storage
SubCategory
ENC = Storage Enclosr
225