Pdr62, Pdr63 – Dell PowerEdge VRTX User Manual
Page 459

LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR62
Message
The rebuild failed due to errors on the target
arg1
.
Arguments
•
arg1 =
physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
Recommended
Response Action
Replace the target disk. If a rebuild does not automatically start after replacing the disk, then
initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the
rebuild.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR63
Message
A bad disk block on
arg1
cannot be reassigned during a write operation.
Arguments
•
arg1 =
physical disk
Detailed
Description
A write operation cannot complete because the disk contains bad disk blocks that could not be
reassigned. Data loss may have occurred. Data redundancy may be lost.
Recommended
Response Action
Replace the disk.
Category
Storage
SubCategory
PDR = Physical Disk
459