beautypg.com

Pdr62, Pdr63 – Dell PowerEdge VRTX User Manual

Page 459

background image

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR62

Message

The rebuild failed due to errors on the target

arg1

.

Arguments

arg1 =

physical disk

Detailed
Description

It is not possible to rebuild data that resides on a defective disk.

Recommended
Response Action

Replace the target disk. If a rebuild does not automatically start after replacing the disk, then
initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the
rebuild.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR63

Message

A bad disk block on

arg1

cannot be reassigned during a write operation.

Arguments

arg1 =

physical disk

Detailed
Description

A write operation cannot complete because the disk contains bad disk blocks that could not be
reassigned. Data loss may have occurred. Data redundancy may be lost.

Recommended
Response Action

Replace the disk.

Category

Storage

SubCategory

PDR = Physical Disk

459