The Chassis Management Controller is unable to communicate with the iDRAC service
processor for the Server identified in the message and the Server could not be turned off. This
situation may occur when iDRAC is rebooting.
Recommended
Response Action
Do the following: 1) Wait for a few minutes for the iDRAC service processor to complete
startup. 2) Retry the operation. 3) If the issue persists, reset the iDRAC and wait a few minutes
for the iDRAC startup to complete before retrying the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 1 (Critical)
Trap/EventID
8417
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PWR8566
Message
Unable to turn off the Server
arg1
before the Power Off timer expired.
Arguments
•
arg1 =
server number
Detailed
Description
Unable to turn off the Server before the Power Off timer has expired. This happens if the Server
did not show "power off" status change within 30 seconds after the operation was initiated.
This situation may also occur when iDRAC is rebooting.
Recommended
Response Action
The Server may need more time to turn off. Wait for ten seconds and check the power status. If
the Server was not turned off, retry the operation. If the issue persists, remove and reinsert the
Server, wait for the iDRAC to complete startup, and retry the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
579