beautypg.com

Tmp0203, Tmp0204 – Dell PowerEdge VRTX User Manual

Page 826

background image

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

TMP0203

Message

CPU

arg1

temperature is greater than the upper critical threshold.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded.

Recommended
Response Action

Check system operating environment, fans, and heatsinks.

Category

System Health

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

CPU temperature is outside of range. Check fans

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

TMP0204

Message

CPU

arg1

temperature is outside of range.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded.

Recommended
Response Action

Check system operating environment, fans, and heatsinks.

Category

System Health

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

826