Swc8611, Swc8612 – Dell PowerEdge VRTX User Manual
Page 781
SWC8611
Message
Profile "
arg1
" and Server (Service Tag:
arg2
in Slot
arg3
are not compatible.
Arguments
•
arg1 =
profile_name
•
arg2 =
service tag
•
arg3 =
server_number
Detailed
Description
The selected profile version and the target server are not compatible. The CMC cannot perform
the cloning operation.
Recommended
Response Action
Select the correct version of profile and/or server and retry the operation
Category
Audit
SubCategory
SWC = Software Config
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
SWC8612
Message
Failed to Fully Extract Boot Device from Stored Profile:
arg1
Arguments
•
arg1 =
key_properties
Detailed
Description
The selected profile is corrupt. Recreate a new profile with the desired properties, or use a
different profile.
Recommended
Response Action
Recreate or use a different profile.
Category
Audit
SubCategory
SWC = Software Config
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
781