beautypg.com

Ctl13, Ctl14 – Dell PowerEdge VRTX User Manual

Page 167

background image

Detailed
Description

The controller and attached enclosures are not cabled correctly.

Recommended
Response Action

Refer to the storage hardware documentation for information on correct cabling
configurations.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 1 (Critical)

Trap/EventID

4329

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL13

Message

The

arg1

cache has been discarded.

Arguments

arg1 =

Controller name

Detailed
Description

The controller has flushed the cache and all data in the cache has been lost. This may occur
when the system has memory or battery problems that cause the controller to distrust the
cache. Although user data may have been lost, this alert does not always indicate that relevant
or user data has been lost.

Recommended
Response Action

Verify that the battery and memory are functioning properly.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL14

Message

Single-bit ECC error limit exceeded on the

arg1

DIMM.

167