Enc23, Enc24 – Dell PowerEdge VRTX User Manual
Page 223

ENC23
Message
arg1
Bad PHY
arg2
Arguments
•
arg1 =
Enclosure Name
•
arg2 =
args
Detailed
Description
There is a problem with a physical connection or PHY.
Recommended
Response Action
Contact the Dell Technical Support at support.dell.com.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC24
Message
Communication with
arg1
is intermittent.
Arguments
•
arg1 =
enclosure name
Detailed
Description
The controller is not receiving a consistent response from the enclosure. There could be a
firmware problem or an invalid cabling configuration. If the cables are too long, they degrade
the signal.
Recommended
Response Action
Power down all enclosures attached to the system and reboot . If the problem persists,
upgrade the firmware to the latest supported version. Verify the cable configuration is valid.
See the storage hardware documentation for valid cabling configurations.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
223