Enc2, Enc3 – Dell PowerEdge VRTX User Manual
Page 212

Severity
Severity 3 (Informational)
Trap/EventID
4339
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC2
Message
arg1
was removed..
Arguments
•
arg1 =
Enclosure Management Module Name
Detailed
Description
An Enclosure Management Module (EMM) was removed.
Recommended
Response Action
Reinsert the Enclosure Management Module (EMM). See the storage hardware documentation
for information on replacing the EMM.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC3
Message
arg1
is shutdown.
Arguments
•
arg1 =
Enclosure Name
Detailed
Description
The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable
temperature range.
Recommended
Response Action
Check for factors that may cause overheating or excessive cooling. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and examine whether
the enclosure is located near a heat source. Make sure the enclosure has enough ventilation
and that the room temperature is not too hot or too cold. Refer to the enclosure documentation
for more diagnostic information.
212