beautypg.com

Pci1346, Pci1348 – Dell PowerEdge VRTX User Manual

Page 410

background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1346

Message

A software error was detected on a component at slot

arg1

.

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

Reboot the system and update the component drivers.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1348

Message

A PCI parity error was detected on a component at slot

arg1

.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded, or system may fail to operate.

Recommended
Response Action

Cycle input power, update component drivers, if device is removable, re-install the device.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

PCI parity error on slot . Reseat PCI card

410