beautypg.com

Swc8604, Swc8605 – Dell PowerEdge VRTX User Manual

Page 777

background image

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

SWC8604

Message

Quick Deploy Profile: Server

arg1

cannot accept profile.

Arguments

arg1 =

server number

Detailed
Description

The target server does not support server cloning.

Recommended
Response Action

No response action is required

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

SWC8605

Message

Quick Deploy Profile: Server

arg1

is unknown version

Arguments

arg1 =

server number

Detailed
Description

The target server replied with incorrect version information.

Recommended
Response Action

Check the target server for correct operation.

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

777