beautypg.com

Pwr8569, Pwr8570 – Dell PowerEdge VRTX User Manual

Page 581

background image

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8569

Message

Unable to power cycle the server

arg1

because the server is off.

Arguments

arg1 =

slot number

Detailed
Description

The requested power cycle operation cannot be performed when the server is not turned on.
The server should be already turned on for the power cycle operation to be successful.

Recommended
Response Action

Turn on the server, if necessary, before requesting a power cycle operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8570

Message

Unable to communicate to the iDRAC, when trying to power cycle the server

arg1

.

Arguments

arg1 =

slot number

Detailed
Description

The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore, the server could not be power cycled. This situation may
occur when iDRAC is rebooting.

Recommended
Response Action

Wait for few minutes, and then retry the operation. If the issue persists, do one of the following:
1) Reset the iDRAC, 2) Perform a Virtual Reseat of the server, 3) Remove and re-insert the
server.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

581