Vdr15, Vdr16 – Dell PowerEdge VRTX User Manual
Page 865
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR15
Message
Initialization of
arg1
was cancelled.
Arguments
•
arg1 =
virtual disk
Detailed
Description
The initialization operation could not be completed. This may be due to a user action or a
physical disk failure.
Recommended
Response Action
If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR16
Message
Consistency check of
arg1
failed.
Arguments
•
arg1 =
virtual disk
Detailed
Description
A physical disk included in the virtual disk failed or there is an error in the parity information. A
failed physical disk causes errors in parity information.
Recommended
Response Action
Check that all the physical disks of the virtual disk are in a healthy condition. Replace any disks
that are not healthy and restart the operation. If this is not the problem, delete the virtual disk
and restore the data to the disk from a backup copy.
Category
Storage
SubCategory
VDR = Virtual Disk
865