Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
IOV1004
Message
Too many slots provided as parameters to Assign and UnAssign Servers methods.
Detailed
Description
The parameters for the method identified in the message are not passed correctly.
Recommended
Response Action
Refer to the Dell Chassis PCI Management Profile document and provide the required
parameters.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
IOV1005
Message
Invalid slot FQDD
arg1
.
Arguments
•
arg1 =
FQDD value
Detailed
Description
The FQDD (Fully Qualified Device Descriptor) entered for the operation does not map to any
instance of the DCIM_ChassisPCISlot class.
Recommended
Response Action
Perform the Enumerate operation on the DCIM_ChassisPCISlot class to determine the the
correct FQDD value for the required slot. Retry the operation with the correct FQDD value.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
313